Product Number:MDV3020A,MDV3200A,MDV3200F
Product Usage:The dispensing machine needle nozzle is mainly used to accurately control the flow of glue to avoid wire drawing, thereby improving the quality and efficiency of dispensing.
Applicable Industries:It is suitable for various types of glue and is widely used in precision dispensing operations in industries such as electronics, automobiles and LEDs.
National Advisory Hotline:
+86 18975335491VERMES Dispensing head nozzle tappet seals for MDV 3020A, MDV 3200A, MDV 3200F, MDV 3250 Series
Since there are many types of dispensing head parts for MDV 3020A, MDV 3200A, MDV 3200F, MDV 3250, only some of the dispensing head nozzle needle parts are displayed. If you want to know the specific specifications and models, please contact customer service.
Order Number | vermes name serial number | Applicable firing pin |
1014157 | N11-60 | CTF/TTF 4-15,CTL15 |
1010343 | N11-70 | CTF/TTF 4-15,CTL15 |
1013254 | N11-75 | CTF/TTF 4-15, CTL15 |
1013255 | N11-80 | CTF/TTF 4-15,CTL15 |
1013129 | N11-90 | CTF/TTF 4-15,CTL15 |
1009837 | N11-100 | CTF/TTF 4-15,CTL15 |
1010344 | N11-120 | CTF/TTF 4-15,CTL15 |
1009838 | N11-150 | CTF/TTF 4-15,CTL15 |
1009839 | N11-200 | CTF/TTF 4-15,CTL15 |
1013024 | N11-300 | CTF/TTF 7-15,CTL15 |
1013025 | N11-400 | CTF/TTF 7-15,CTL15 |
1013444 | N13-30 | CTF/TTF 4-15,CTL15 |
1013443 | N13-40 | CTF/TTF 4-15,CTL15 |
1013378 | N13-45 | CTF/TTF 4-15,CTL15 |
1012846 | N13-50 | CTF/TTF 4-15,CTL15 |
1013393 | N13-60 | CTF/TTF 4-15,CTL15 |
1013344 | N13-70 | CTF/TTF 4-15,CTL15 |
1011781 | N13-75 | CTF/TTF 4-15,CTL15 |
1013345 | N13-80 | CTF/TTF 4-15,CTL15 |
Product Categories | Product Number | Product Name |
Vermes supplies | 1013327 | Sealing ring (hot glue) |
1013006 | O-ring (green) | |
1013008 | O-ring (black) | |
1007067 | U-shaped sealing ring | |
1009419 | Base sealing ring | |
Vermes wearing parts | 1013361 | Metal guide ring |
1012273 | Peek guide ring | |
1009012 | Nozzle adjustment nut | |
1013168 | Liquid Box | |
1013164 | PEEK liquid box | |
1007060 | Cartridge connector | |
1010026 | Fluid box connection block | |
1012846 | 0.05mm nozzle | |
1009837 | 0.1mm nozzle | |
1009838 | 0.15mm nozzle | |
1013176 | TTF15 firing pin | |
1013183 | TTF10 firing pin | |
1013182 | TTF7 firing pin | |
1012893 | CTF7 firing pin | |
1012888 | CTF10 firing pin | |
Vermes maintenance tools | 1011208 | 100um wire |
1010314 | Cleaning brush | |
1013266 | Cotton swab | |
1010313 | Small cotton swab | |
501118 | Special paraffin wax | |
50119 | Tappet lubricant | |
vermestools | 1010208 | Sealing ring removal tool |
1008344 | Strike pin removal tool | |
1007083 | Nozzle removal tool | |
1013324 | Nozzle Clearance Tool |
Ⅸ、Manufacturing capabilities of dispensing nozzles, push rods and other parts:
Ⅹ、MDS 3000 Dispensing Tappet and Nozzle:
1、High precision: MDS 3000 series dispensing nozzles have excellent precision and repeatability, and can accurately control the amount and position of liquid injection. They are suitable for application scenarios that require high dispensing quality.
2、Flexibility: The dispensing system provides a variety of nozzle and tappet options to meet dispensing tasks with different viscosities, flow rates and accuracy requirements.
3、Reliability: Using advanced engineering design and materials manufacturing, MDS 3000 dispensing system tappets and nozzles have excellent durability and stability, and are suitable for long-term and high-volume production environments.
4、Automation integration: The tappet and nozzle of the dispensing system support integration with various automated machines, and can realize automated control and production line integration through various control interfaces to improve production efficiency and quality.
Ⅺ、MDS 1000 Dispensing Tappet and Nozzle:
1. Affordable: The MDS 1000 dispensing system is an economical choice, suitable for cost-sensitive application scenarios, and can reduce investment costs without sacrificing quality.
2. Easy to use: This series of dispensing tappets and nozzles are simple in design, easy to install and operate, and can be used without complicated training. They are suitable for small production lines or applications that require quick replacement of dispensing valves.
3. Adaptability: MDS 1000 dispensing tappets and nozzles are suitable for a range of different glues and applications, and can meet the needs of common dispensing tasks, such as packaging, assembly, etc.
4. Reliability: MDS 1000 series dispensing valve nozzles have good reliability and durability and can meet the needs of general dispensing tasks.
In summary, the MDS 3000 series dispensing system nozzles and tappets are suitable for high-end applications that require higher accuracy and stability, while the MDS 1000 series dispensing valves are suitable for general points that are cost-sensitive and have less stringent requirements. Glue task, which series to choose depends on specific application needs and budget considerations.